  • CONNECSYS 50/125µm OM2 multimode fibre is a graded-index multimode optical fibre with a 50µm core diameter and a 125μm cladding diameter. The optical fibre is comprehensively optimized for the performance at the 850nm and 1300nm operating wavelengths, which meet the requirement of EN187000 and TIA/EIA 568 of maximum attenuation of ≤ 3.5 dB at 850nm and ≤ 1.5 dB at 1300nm wavelengths. The optical fibre also complies with the ITU-T Recommendation G.651 and IEC 793-2 Type A1 Optical Fibre Specification. With the optical fibre low attenuation and high bandwidth, it overfills the transmission demand of IEEE 802.3z Gigabit Ethernet.
Optical Characteristics
CharacteristicsConditionsSpecified Values
Attenuation850 nm
1300 nm
≤ 2.3 dB/km
≤ 0.6 dB/km
Minimum Modal Bandwidth850 nm
1300 nm
600 MHz/km
1200 MHz/km
Numerical Aperture0.200 ± 0.015
Zero Dispersion Wavelength1295 – 1320 nm
Zero Dispersion Slope1295 – 1300 nm
1300 – 1320 nm
≤ 0.001 X (λ0 - 1190) ps/(nm2 ∙ km)
≤ 0.11 ps/(nm2 ∙ km)
Group Index of Refraction850 nm
1300 nm
1.482
1.477
Backscatter Characteristics ( @ 1300 nm )
Step (Bidirectional Measurement)≤ 0.10 dB
Irregularities over fibre length and point discontinuity ≤ 0.10 dB
Attenuation Uniformity≤ 0.08 dB/km
Geometrical Characteristics
Core Diameter50 ± 2.5 μm
Cladding Diameter124.8 ± 1.0 μm
Cladding Non-Circularity≤ 1.0 %
Coating Diameter245 ± 7 μm
Coating – Cladding Concentricity Error≤ 12.0 μm
Coating Non-Circularity≤ 6.0 %
Core – Cladding Concentricity Error≤ 1.5 μm
Environmental Characteristic ( @ 850 nm & 1300 nm )
Temperature Dependence Induced Attenuation at-60°C to +85°C≤ 0.10 dB/km
Temperature - Humidity Cycling Induced Attenuation at-10°C to +85°C, 98% RH≤ 0.10 dB/km
Water Soak Dependence Induced Attenuation at23°C, for 30 Days≤ 0.10 dB/km
Damp Heat Dependence Induced Attenuation at85°C & 85% RH, 30 Days≤ 0.10 dB/km
Dry Heat Aging at85ᵒC≤ 0.10 dB/km
Mechanical Specifications
Proof TestOff Line≥ 9.0 N; ≥ 1.0 %; ≥ 100 kpsi
Macro – Bend Induced Attenuation
100 Turns Around a Mandrel of 60 mm Diameter

850 nm & 1300 nm

≤ 0.50 dB
Coating Strip ForceTypical Average Force
Peak Force
1.5 N
≥ 1.3 N ≤ 8.9 N
Dynamic Stress Corrosion Susceptibility Parameter nd ≥ 27