Multi-Mode 50/125 μm OM2 Optical Fibre
Description :
- CONNECSYS 50/125µm OM2 multimode fibre is a graded-index multimode optical fibre with a 50µm core diameter and a 125μm cladding diameter. The optical fibre is comprehensively optimized for the performance at the 850nm and 1300nm operating wavelengths, which meet the requirement of EN187000 and TIA/EIA 568 of maximum attenuation of ≤ 3.5 dB at 850nm and ≤ 1.5 dB at 1300nm wavelengths. The optical fibre also complies with the ITU-T Recommendation G.651 and IEC 793-2 Type A1 Optical Fibre Specification. With the optical fibre low attenuation and high bandwidth, it overfills the transmission demand of IEEE 802.3z Gigabit Ethernet.
Optical Characteristics
Characteristics | Conditions | Specified Values |
Attenuation | 850 nm 1300 nm | ≤ 2.3 dB/km ≤ 0.6 dB/km |
Minimum Modal Bandwidth | 850 nm 1300 nm | 600 MHz/km 1200 MHz/km |
Numerical Aperture | 0.200 ± 0.015 | |
Zero Dispersion Wavelength | 1295 – 1320 nm | |
Zero Dispersion Slope | 1295 – 1300 nm 1300 – 1320 nm | ≤ 0.001 X (λ0 - 1190) ps/(nm2 ∙ km) ≤ 0.11 ps/(nm2 ∙ km) |
Group Index of Refraction | 850 nm 1300 nm | 1.482 1.477 |
Backscatter Characteristics ( @ 1300 nm )
Step (Bidirectional Measurement) | ≤ 0.10 dB |
Irregularities over fibre length and point discontinuity | ≤ 0.10 dB |
Attenuation Uniformity | ≤ 0.08 dB/km |
Geometrical Characteristics
Core Diameter | 50 ± 2.5 μm |
Cladding Diameter | 124.8 ± 1.0 μm |
Cladding Non-Circularity | ≤ 1.0 % |
Coating Diameter | 245 ± 7 μm |
Coating – Cladding Concentricity Error | ≤ 12.0 μm |
Coating Non-Circularity | ≤ 6.0 % |
Core – Cladding Concentricity Error | ≤ 1.5 μm |
Environmental Characteristic ( @ 850 nm & 1300 nm )
Temperature Dependence Induced Attenuation at | -60°C to +85°C | ≤ 0.10 dB/km |
Temperature - Humidity Cycling Induced Attenuation at | -10°C to +85°C, 98% RH | ≤ 0.10 dB/km |
Water Soak Dependence Induced Attenuation at | 23°C, for 30 Days | ≤ 0.10 dB/km |
Damp Heat Dependence Induced Attenuation at | 85°C & 85% RH, 30 Days | ≤ 0.10 dB/km |
Dry Heat Aging at | 85ᵒC | ≤ 0.10 dB/km |
Mechanical Specifications
Proof Test | Off Line | ≥ 9.0 N; ≥ 1.0 %; ≥ 100 kpsi |
Macro – Bend Induced Attenuation 100 Turns Around a Mandrel of 60 mm Diameter | 850 nm & 1300 nm | ≤ 0.50 dB |
Coating Strip Force | Typical Average Force Peak Force | 1.5 N ≥ 1.3 N ≤ 8.9 N |
Dynamic Stress Corrosion Susceptibility Parameter nd | ≥ 27 |