Home | Product | Fibre Optic Cable | Optical Fibre | Multi-Mode 50/125 μm OM3 Optical Fibre

PRODUCTS

Multi-Mode 50/125 μm OM3 Optical Fibre

Description :
  • CONNECSYS 50/125μm OM3 multimode fibre is a graded-index multimode optical fibre complies with ISO/IEC 11801 OM3 specification, IEC 60793-2-10 type A1a.2 Optical Fibre Specification, and TIA/EIA-492AAAC detail specification.
Optical Characteristics
CharacteristicsConditionsSpecified Values
Attenuation850 nm
1300 nm
≤ 2.3 dB/km
≤ 0.6 dB/km
Overfilled Modal Bandwidth850 nm
1300 nm
≥ 1500 MHz/km
≥ 500 MHz/km
Effective Modal Bandwidth850 nm≥ 2000 MHz/km
10 Gb/s Ethernet Link Distance SX(850 nm)≥ 300 m
Differential Mode Delay (DMD) 850 nmSee Note 1
Numerical Aperture0.200 ± 0.015 NA
Zero Dispersion Wavelength1295 – 1320 nm
Zero Dispersion Slope1295 – 1300 nm
1300 – 1320 nm
≤ 0.001 X (λ0 - 1190) ps/(nm2 ∙ km)
≤ 0.11 ps/(nm2 ∙ km)
Group Index of Refraction850 nm
1300 nm
1.482
1.477
Backscatter Characteristics ( @ 1300 nm )
Step (Bidirectional Measurement)≤ 0.10 dB
Irregularities Over Fibre Length And Point Discontinuity ≤ 0.10 dB
Difference Backscatter Coefficient (Bidirectional Measurement)≤ 0.08 dB/km
Geometrical Characteristics
Core Diameter50 ± 2.5 μm
Core Non-Circularity≤ 5.0 %
Cladding Diameter124.8 ± 1.0 μm
Cladding Non-Circularity≤ 1.0 %
Coating Diameter245 ± 7 μm
Coating – Cladding Concentricity Error≤ 12.0 μm
Coating Non-Circularity≤ 6.0 %
Core – Cladding Concentricity Error≤ 1.0 μm
Environmental Characteristic ( @ 850 nm & 1300 nm )
Temperature Dependence Induced Attenuation at-60°C to +85°C≤ 0.10 dB/km
Temperature - Humidity Cycling Induced Attenuation at-10°C to +85°C, 98% RH≤ 0.10 dB/km
Water Soak Dependence Induced Attenuation at23°C, for 30 Days≤ 0.10 dB/km
Damp Heat Dependence Induced Attenuation at85°C & 85% RH, 30 Days≤ 0.10 dB/km
Dry Heat Aging at85ᵒC≤ 0.10 dB/km
Mechanical Specifications
Proof TestOff Line≥ 9.0 N; ≥ 1.0 %; ≥ 100 kpsi
Macro – Bend Induced Attenuation
100 Turns Around a Mandrel of 60 mm Diameter

850 nm & 1300 nm

≤ 0.50 dB
Coating Strip ForceTypical Average Force1.5 N
Dynamic Stress Corrosion Susceptibility Parameter nd ≥ 27 nd

Note 1 : DMD specifications are comply with IEC 60793-2-10 (Type A1a.2 for OM3) and TIA-492AAAC (OM3).